Power Requirements: |
100 to 240 VAC (50/60 Hz) at 0.4A Max. |
Enclosure Type: |
Stainless steel wall or desk-mount |
Enclosure Size: |
9.2-in W x 7.5-in H x 3.1-in D (233-mm W x 191-mm H x 79-mm D) |
Weight: |
8.2 lb (3.7 kg) |
Compensated Temperature Range: |
14 to 104 ºF (-10 to 40 ºC) |
Operating Temperature Range: |
-10 to 122 ºF (-23 to 50 ºC) |
Humidity: |
0 to 90% non-condensing |
Transducer Excitation: |
9.4 VDC |
Signal Input Range: |
1.0 mV min. to 40 mV max. (with dead load boost) |
Number of Load Cells: |
8 each 350-ohm load cells |
Load Cell Cable Length: |
1,500 feet (457 m) maximum (requires the use of sense lines). Consult factory for other requirements. 30 feet (9 m) maximum without sense lines. |
Division Value Commercial: |
1, 2, or 5 x 10, 1, 0.1, 0.01, 0.001 |
Division Value Non-commercial: |
1 to 99 x 10, 1, 0.1, 0.01, 0.001 |
Sensitivity Non-commercial: |
0.15 uV/e |
Sensitivity NTEP: |
0.3uV/e (Class III/IIIL) |
Sensitivity Canada: |
0.3uV/e (Class III/IIIHD) |
Sensitivity OIML: |
0.5 uV/e (Class III) |
Scale Divisions Non-commercial: |
100 to 240,000 |
Scale Divisions NTEP: |
500 to 10,000 (Class III/IIIL) |
Scale Divisions Canada: |
500 to 10,000 (Class III/IIIHD) |
Scale Divisions OIML: |
500 to 10,000 (Class III) |
Internal Resolution: |
1 part in 16,777,216 |
Tare Capacity: |
Scale capacity |
Sample Rate: |
1 to 100 samples per second, selectable |
Auto Zero Range: |
0.5 or 1 through 9 divisions |
Weighing Units: |
Tons, Pounds, Pounds-Ounces, Ounces, Metric Tons, Kilograms, Grams |
Keypad: |
Color-coded membrane type, 7 keys |
Standard I/O: |
4 ea serial I/O ports configured as 1 ea 20mA output-only ports (uses one of the four RS-232 ports), 1 ea bi-directional 20mA port (uses one of the four RS-232 ports), and 1 ea USB port (uses one of the four RS-232 ports) |
Certifications: |
NTEP, Measurement Canada, Australian NSC, ETL, and CE |
Display: |
Six-digit, seven-segment, 0.6-in (15-mm) high LED |
Valoraciones